SNDT WOMEN'S UNIVERSITY
BMK Knowledge Resource Centre
Vithaldas Vidyavihar, Juhu Tara Road,
Santacruz (West) Mumbai - 400049
| 000 -LEADER | |
|---|---|
| fixed length control field | 01997nam a2200145 4500 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250821b |||||||| |||| 00| 0 eng d |
| 100 ## - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Farhat Afzah Samoon |
| 245 ## - TITLE STATEMENT | |
| Title | Improved Synchronization Using an Optimized Controller for the Seamless Operation of PV-BES-Based AC Microgrid |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | Pages 183-193 |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. biblio.abstract | In this work, islanding detection, the transition between the modes, optimal grid synchronization capability, and power quality enhancement are ensured in any operating condition of the microgrid. The microgrid under study consists of a 3-phase two-stage grid-connected solar photovoltaic – battery as a storage system. An incremental conductance-based maximum power point algorithm extracts maximum power in both standalone modes of operation and grid-connected modes. Balancing of grid current, reactive power compensation, and power quality improvement is provided by adaptive filtering technique based least mean square algorithm-based voltage source converter. In this system synchronization and seamless change of mode from the grid integration mode (GIM) to standalone integration (SAI) mode of operation is enhanced ant lion optimization (ALO). The error difference between the phase angle of the load and grid is minimized using an ALO-optimized proportional integrator (PI) controller. The results show the ALO-based controller decreases the synchronizing time cycles between the phase angle of load and grid angle, therefore, enhancing synchronization capability with this, the frequency of the grid is further enhanced by ALO-optimized values. Simulation results show the robustness of the voltage source converter (VSC) control. The system remains satisfactory as per IEEE standards under various dynamic and steady-state conditions. |
| 654 ## - SUBJECT ADDED ENTRY--FACETED TOPICAL TERMS | |
| Subject | <a href="aptive control">aptive control</a> |
| -- | <a href="Grid synchronization">Grid synchronization</a> |
| -- | <a href="Microgrid">Microgrid</a> |
| -- | <a href="MPPT">MPPT</a> |
| -- | <a href="Optimization">Optimization</a> |
| -- | <a href="Power quality">Power quality</a> |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | iKHLAQ HUSSAIN |
| 773 0# - HOST ITEM ENTRY | |
| Host Biblionumber | 80270 |
| Host Itemnumber | 113442 |
| Place, publisher, and date of publication | New Delhi IETE |
| Title | IETE Technical Review |
| International Standard Serial Number | 0256-4602 |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Koha item type | Journal Article |
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Location (home branch) | Sublocation or collection (holding branch) | Date acquired | Koha issues (times borrowed) | Piece designation (barcode) | Koha date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | SNDT Juhu | SNDT Juhu | 21/08/2025 | JP864.1 | 21/08/2025 | 21/08/2025 | Journal Article |