SNDT WOMEN'S UNIVERSITY

BMK Knowledge Resource Centre

Vithaldas Vidyavihar, Juhu Tara Road,
Santacruz (West) Mumbai - 400049

Optimization of Vibration Control of Adjacent Buildings Structures by a New Inertial Amplified Mass-Tuned Damper (Record no. 132557)

MARC details
000 -LEADER
fixed length control field 02540nam a2200133 4500
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250822b |||||||| |||| 00| 0 eng d
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Xiaofang Kang
245 ## - TITLE STATEMENT
Title Optimization of Vibration Control of Adjacent Buildings Structures by a New Inertial Amplified Mass-Tuned Damper
300 ## - PHYSICAL DESCRIPTION
Extent p241–258
520 ## - SUMMARY, ETC.
Summary, etc. biblio.abstract Earthquake disaster is a kind of natural disaster that is not controlled by human factors, which is characterized by sudden strong and destructive, and has caused huge loss of life and property to our society. As buildings become denser and denser, a series of chain damages will occur in adjacent buildings under the influence of strong earthquakes, and the vibration damping measures for adjacent buildings in the traditional design scheme can no longer meet the actual functional requirements. Therefore, it is particularly important to explore new and more influence methods of vibration damping. This paper describes the inertial amplified mass-tuned damper (IA-TMD) applied to vibration control of adjacent buildings. The dynamic equations of the vibration system controlled by the IA-TMD under seismic excitation are established. The frequency ratio and damping ratio of the IA-TMD are used as the optimization parameters of the H2 optimization theory to obtain the exact expressions of the optimized system parameters. Analyze the dynamic response of the system under seismic excitation and compare the structural vibration damping property of the mass amplification damper with other controls. The synthesis shows that the optimization influence of IA-TMD on the vibration damping property of adjacent buildings structures is much higher than that of traditional dampers. Four typical seismic waves are selected as external excitations for time-domain analysis, and it is found that IA-TMD has a good damping influence in all time-domain ranges, and its influence is better than that of traditional dampers. The frequency-domain and time-domain analyses of the vibration control system demonstrate that the inertial amplified mass-tuned damper is superior to the traditional damper in vibration control of adjacent buildings structure.
654 ## - SUBJECT ADDED ENTRY--FACETED TOPICAL TERMS
Subject <a href="Applied Dynamical Systems ">Applied Dynamical Systems </a>
-- <a href="Architectural Acoustics ">Architectural Acoustics </a>
-- <a href="Multibody Systems and Mechanical Vibrations ">Multibody Systems and Mechanical Vibrations </a>
-- <a href="Noise Control Structural Mechanics Structural Materials">Noise Control Structural Mechanics Structural Materials</a>
-- <a href="Structural Mechanics ">Structural Mechanics </a>
-- <a href="Structural Materials">Structural Materials</a>
773 0# - HOST ITEM ENTRY
Host Biblionumber 80299
Host Itemnumber 113444
Place, publisher, and date of publication Germany Springer Nature India Private limited
Title Journal of the Institution of engineers (India): series A
International Standard Serial Number 2250-2149
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Journal Article
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Location (home branch) Sublocation or collection (holding branch) Date acquired Koha issues (times borrowed) Piece designation (barcode) Koha date last seen Price effective from Koha item type
    Dewey Decimal Classification     SNDT Juhu SNDT Juhu 22/08/2025   JP866.17 22/08/2025 22/08/2025 Journal Article